This article is a placeholder for upcoming articles describing the SNMP items below.
Overall System Status — .1.3.6.1.4.1.674.10892.5.2.1.0
LCD Status — .1.3.6.1.4.1.674.10892.5.2.2.0
System Storage — .1.3.6.1.4.1.674.10892.5.2.3.0
Intrusion Status — .1.3.6.1.4.1.674.10892.5.4.300.70.1.5.1.1
Chassis Status — .1.3.6.1.4.1.674.10892.5.4.200.10.1.4.1
** Power Status
.1.3.6.1.4.1.674.10892.5.4.200.10.1.9.1
1: Other
2: Unknown
3: ok
4: nonCritical
5: Critical
6: nonRecoverable
** Power- Voltage
.1.3.6.1.4.1.674.10892.5.4.200.10.1.12.1
1: Other
2: Unknown
3: ok
4: nonCritical
5: Critical
6: nonRecoverable
** Power - Amperage
.1.3.6.1.4.1.674.10892.5.4.200.10.1.15.1
1: Other
2: Unknown
3: ok
4: nonCritical
5: Critical
6: nonRecoverable
** Cooling Status (Combined)
.1.3.6.1.4.1.674.10892.5.4.200.10.1.21.1
1: Other
2: Unknown
3: ok
4: nonCritical
5: Critical
6: nonRecoverable
** Temperature Status (Combined)
.1.3.6.1.4.1.674.10892.5.4.200.10.1.24.1
1: Other
2: Unknown
3: ok
4: nonCritical
5: Critical
6: nonRecoverable
** Memory Status (Combined)
.1.3.6.1.4.1.674.10892.5.4.200.10.1.27.1
1: Other
2: Unknown
3: ok
4: nonCritical
5: Critical
6: nonRecoverable
** Processor Status (Combined)
.1.3.6.1.4.1.674.10892.5.4.200.10.1.50.1
1: Other
2: Unknown
3: ok
4: nonCritical
5: Critical
6: nonRecoverable
** Battery Status (Combined)
.1.3.6.1.4.1.674.10892.5.4.200.10.1.52.1
1: Other
2: Unknown
3: ok
4: nonCritical
5: Critical
6: nonRecoverable
Memory Slot 1
.1.3.6.1.4.1.674.10892.5.4.1100.50.1.5.1.1
Memory Slot 2
.1.3.6.1.4.1.674.10892.5.4.1100.50.1.5.1.1
RAID Controller Name
.1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.2.1
STRING
RAID Controller FW Version
.1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.8.1
STRING
RAID Controller Cache Size
.1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.9.1
INTEGER
RAID Controller Rollup Status
.1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.37
RAID Controller Status
.1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.38.1
INTEGER
1: Other
2: Unknown
3: ok
4: nonCritical
5: Critical
6: nonRecoverable
RAID Controller Driver Version
.1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.41
INTEGER
Phy Disk #1 State
.1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.4.1
Phy Disk #2 State
.1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.4.2
Phy Disk #1 Component Status
.1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.24.1
Phy Disk #2 Component Status
.1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.24.2
Virtual Disk #01 Name
.1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.2.1
Virtual Disk #01 State
.1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.4.1
1: The current state could not be determined.
2: *The virtual disk is operating normally or optimally.
3: The virtual disk has encountered a failure. The data on disk
is lost or is about to be lost.
4: The virtual disk encounterd a failure with one or all of the
constituent redundant physical disks. The data on the virtual
disk might no longer be fault tolerant.
Virtual Disk #01 RAID
.1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.13.1
1: Not one of the following
2: RAID-0
3: RAID-1
4: RAID-5
5: RAID-6
6: RAID-10
7: RAID-50
8: RAID-60
9: concatRAID-1
10: concatRAID-5
Virtual Disk #01 Status
.1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.20.1
1: Other.
2: Unknown.
3: *OK.
4: Non-critical
5: Critical
6: nonRecoverable